Gas Burner Ignition Sequence
To understand how the ignition sequence works we must first break it down into the types of systems. The first is the hot surface igniter type system (HSI) which is essentially a small electric heating element somewhat like an electric oven heating element. The other common types are either an intermittent pilot where the pilot is lit when needed or a standing pilot where the pilot stays lit much like on a standard gas water heater. There is also one other type that is not very common on gas furnaces but is standard on most oil furnaces and that is the spark ignition.
Intermittent Spark or Standing Pilot Ignition
Intermittent Spark ignition Pilot Light Assembly For the Intermittent Pilot Ignition type, after the control board has confirmed that the inducer fan is in fact running or in the case with no inducer fan upon a call for heating the heating system will open the pilot gas valve which is part of the main gas valve assembly and send high voltage to the spark igniter.
Read more of this and other great articles at http://www.asi-heating-airconditioning.com/About_GasBurner_Ignition.html
Ameri-Serv, Inc.
Heating and Cooling
Facilities Services
13601 W. Mc Millan Rd. S/102-120
Boise, Idaho 83713
Ada County (208) 342 4328
Canyon County (208) 467-2665
http://www.asi-heating-airconditioning.com
Serving the Treasure Valley with Honest and Dependable Services at Consistently Affordable Prices for all your heating and cooling needs. 100% Satisfaction always Guaranteed. Residential and Commercial Sales Installation, Repairs and Services on all brands and system types. Gas, Oil, Electric Furnaces - Heat Pumps – Air Conditioning – Dual Fuel Green Hybrid Systems – Geo Thermal Systems – Indoor Air Quality – Building Automation